Our long-awaited anode replacement has encountered yet another delay. The anode is awaiting annealing—a heating and cooling process need to strengthen beryllium (and many other metals) after machining. The beryllium annealing process has to be done in a helium-filled chamber to avoid oxidation or other chemical reactions with the heated metal. However, the company that does our annealing has run out of helium and won’t be resupplied until the new year, so we won’t get the anode back until early January.
In the meantime, the lab is undergoing a high-intensity cleaning. After the anode broke in August and a new disassembly and assembly was needed, Research Scientist Dr Syed Hassan pointed out that we had not had blood tests in a long time to confirm that our safety procedures were working. That reminded Chief Scientist Eric Lerner that we had not tested the dust in the lab for too long as well—since 2019.
Fortunately, the blood tests for lead came back as normal. But the dust tests detected both beryllium and lead in the dust. The beryllium level was 30 times less than OSHA safety standards but the lead was significantly more than the OSHA standards. So, despite the lack of health consequences for us, we had to temporarily close the lab until we can have a professional crew clean everything of the dust. We expect this to happen in December.
We’ve identified the sources of both the lead and the beryllium. We use lead bricks to add mass on the top of the machine because the magnetic fields generated during firing push the upper and lower plates apart. The lead bricks are wrapped in tape to prevent the formation of dust. In 2021, we noted that earlier wrappings had torn. We decided to replace the lead bricks with steel plates from exercise machines, an economical choice. However, in the months after the pandemic lock-down, there was a shortage of exercise equipment and we could only replace half the lead. So, we re-wrapped the rest securely and cleaned the dust routinely.
Subsequently we made two oversights. First, we did not test the dust to see if all the lead was gone and we forgot to replace the rest of the lead when the steel plates became available. As the safety experts we consulted this month explained, the lead dust almost certainly accumulated in the heating system ducts and was slowly recirculated into the lab over the years.
As part of the clean-up, we are now getting all the lead out of the lab and putting in all steel plates. The cleaning crew will clean out all the ducts. We’ll talk about the much smaller beryllium dust problem in the next report.